Major components: contact plate 1; pole pieces 2; usage design: used to shield arc whenever the circuit is interrupted; mtg configuration: contact plate mtd on pin and bolted in place through arc chute support;
Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height
Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts
NSN 5996-00-548-6482
NSN 6645-00-900-5830
NSN 5835-01-187-8986
NSN 6610-01-083-1446
NSN 5999-01-526-4752
NSN 6110-00-294-4067
NSN 5945-01-169-4838
NSN 5990-01-054-3227
NSN 5905-01-567-7263
NSN 5930-00-901-4411
NSN 5998-00-519-0741
NSN 6130-00-138-0649